About This Lab
Three topics across two scales: riverbank groundwater follows hydraulic head elevation (m), while the upstream reservoir tracks hourly volume balance (10³ m³).
Groundwater is not an underground river or subterranean lake; it occupies interconnected pores and fractures within sand, gravel, and rock. Above the water table lies the unsaturated vadose zone containing air and capillary film water; below it lies the saturated aquifer bounded at the base by an impermeable aquiclude.
Whether a river recharges groundwater or groundwater feeds the river depends solely on hydraulic head under a unified elevation datum: water flows from higher head to lower head. Raising river stage (H > a) drives bank filtration into the aquifer; lowering river stage (H < a) reverses flow into baseflow discharge, propagating inland with distance-dependent lag.
Three Core Takeaways
Three Core Takeaways
- Aquifer & observation wells: slotted well screens connect directly to the aquifer, so static well water elevation equals local hydraulic head. With ground at 14.0 m, water table at 10.00 m, and base at 6.0 m, both depth to water and saturated thickness equal 4.00 m.
- Two-way exchange & pumping cone: from a 10.00 m equilibrium, raising river head to 12.0 m for 300 s lifts near/mid/far wells to 11.700 / 11.184 / 10.889 m; lowering to 8.0 m drops them symmetrically to 8.300 / 8.816 / 9.111 m. Pumping the mid well at 0.03 m³/s for 300 s draws the mid well down to 7.170 m below both neighbors (9.112 m and 7.778 m), forming a cone of depression.
- Reservoir regulation & conservation bounds: storage shaves a 60×10³ m³/h inflow peak down to a steady 20×10³ m³/h planned release, bounded by the 100×10³ m³ capacity ceiling and 0×10³ m³ empty floor. Under a 120×10³ m³/h flood peak, Hours 3 and 4 each spill 20×10³ m³, raising total downstream outflow to 40×10³ m³/h.
Models & Sources
Models & Sources
- Three-cell discrete river-aquifer model: simplified linear Darcy storage-diffusion with specific yield Sy = 1 m³/m, step Δt = 1 s, river-near conductance 0.02 m²/s, and inter-well conductance 0.01 m²/s. Staff gauge resolution is 0.01 m; |H − a| < 0.01 m is reported as no discernible gradient within resolution.
- Hourly equal-area reservoir water-balance model: enforces strict conservation with actual release = min(planned, S_start + I), spill = max(0, S_start + I − actual − 100), and S_end = S_start + I − actual − spill. Evaporation, seepage, and hydropower head conversion are omitted.
- NGWA & USGS Water Science School · Aquifers and Groundwater ↗ NGWA & USGS Water Science School: pore-hosted aquifers, water table, and unsaturated zone definitions, verified 2026-04
- Winter et al. 1998 · USGS Circular 1186: Ground Water and Surface Water ↗ USGS Circular 1186 · Ground Water and Surface Water: A Single Resource: two-way stream-aquifer exchange and pumping cones, verified 2026-04